- LC 10 W 150–400 mA flexC C EXC
- LC 17 W 250–700 mA flexC C EXC
- LC 25 W 350–1050 mA flexC C EXC
- LC 45 W 500–1400 mA flexC C EXC
- LC 60 W 900–1750 mA flexC C EXC
- LC 100 W 1100–2100 mA flexC C EXC
- LC 14 W 100-400 mA flexC NF SC EXC3
- LC 28 W 300-700 mA flexC NF SC EXC3
- LC 38 W 650-1050 mA flexC NF SC EXC3
- LC 10 W 150–400 mA flexC SC EXC
- LC 17 W 250–700 mA flexC SC EXC
- LC 25 W 350–1050 mA flexC SC EXC
- LC 45 W 500–1400 mA flexC SC EXC
- LC 10 W 150–400 mA flexC SR EXC
- LC 17 W 250–700 mA flexC SR EXC
- LC 25 W 350–1050 mA flexC SR EXC
- LC 45 W 500–1400 mA flexC SR EXC
- LC 60 W 900–1750 mA flexC SR EXC
- LC 100 W 1100–2100 mA flexC SR EXC
- LC 20 W 100-1050 mA NF SR EXC3
- LC 27 W 100-500 mA NF SR EXC3
- LC 45 W 450-1050 mA NF SR EXC3
- Série advanced
- Série advanced circulaire
- Série essence
- Série excite
- Drivers in-track graduables
- Drivers in-track à sortie constante
- DC-String
- Drivers à tension constante
- Tension universelle (UNV)
- Matter components
- Accessoires
- Modules LED
- Tunable White
- Composants d’éclairage de secours
- Commande de l’éclairage et mise en réseau
- Drivers LED
- Applications
- Éclairage connecté
- Projets
- Services
- Caractéristiques techniques
- Contact
- Home
- Produits
- ►
- Drivers LED
- ►
- Drivers compacts à sortie constante
- ►
- Série excite
- ►
- LC 100 W 1100–2100 mA flexC SR EXC
Driver LC 100 W 1100–2100 mA flexC SR EXC
Série excite
Description du produit
- Convertisseur indépendant à LED à courant constant
- Courant de sortie réglable entre 1100 et 2100 mA avec l'interface ready2mains ou les connecteurs I-SELECT (génération 2)
- Puissance de sortie max. 100 W
- Jusqu'à 92 % d'efficacité
- Durée de vie nominale jusqu'à 100 000 h
- 5 ans de garantie (voir les conditions sous www.tridonic.com)
Caractéristiques du boîtier
- Boîtier: polycarbonate, blanc
- Classe de protection IP20
- Serre-câbles avec possibilité de branchement en dérivation
Interfaces
- ready2mains (configuration via le secteur)
- Borniers: borniers à enfichage 0° / 45° (entrée / sortie)
Fonctions
- Courant de sortie réglable par pas de 1 mA (ready2mains, I-SELECT 2)
- Fonctions de protection (protection contre : la surchauffe, les courts-circuits, les surcharges, la tension à vide ; plage de tension d'entrée)
- Convient pour les installations d'éclairage de secours conformes à la norme EN 50172
- Pour des diamètres de câbles jsuqu'à 2,5 mm²
Avantages
- Fenêtre d'exploitation orientée application pour une compatibilité maximum
- Économies d'énergie élevées grâce à la grande efficacité
- Configuration flexible via ready2mains et I-SELECT 2
- Montage sans outil
Application typique
- Pour applications en tant que downlight, panneau et luminaires à hauteur élevée/faible
Données de commande | ||||
---|---|---|---|---|
Type | Référence | Emballage carton | Emballage palette | Poids par pièce |
LC 100W 1100-2100mA flexC SR EXC | 28001573 | 10 pièce/pièces | 300 pièce/pièces | 0,351 kg |
- Types de luminaires :
-
-
-
-
- Marque de contrôle :
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Caractéristiques techniques | |
---|---|
Gamme de tension d'alimentation | 220 – 240 V |
Plage de tension d'alimentation AC | 198 – 264 V |
Plage de tension continue | 176 – 280 V |
Fréquence réseau | 0 / 50 / 60 Hz |
Protection contre les surtensions | 320 V AC, 48 h |
Courant nominal type (à 230 V, 50 Hz, à pleine charge) (1) | 482 mA |
Courant typique (220 V, 0 Hz, pleine charge, 66 % de niveau de gradation) (1) | 342 mA |
Courant de fuite (à 230 V, 50 Hz, pleine charge) (1) | < 250 µA |
Puissance d'entrée max. | 109 W |
Efficacité typique (à 230 V, 50 Hz, pleine charge) (1) | 92 % |
λ (à 230 V, 50 Hz, pleine charge) | 0,95 |
Courant d'entrée typique en tension à vide | 60 mA |
Puissance d'entrée typique en tension à vide | 0,111 W |
Courant d'appel (crête / durée) | 50,6 A / 210 µs |
THD (à 230 V, 50 Hz, pleine charge) | < 10 % |
Temps d'amorçage (avec 230 V, 50 Hz, pleine charge) | < 500 ms |
Temps d'amorçage (mode DC) | < 500 ms |
Temps de commutation (AC/DC) (2) | < 0,3 s |
Temps de déconnexion (à 230 V, 50 Hz, à pleine charge) | < 50 ms |
Tolérance de courant de sortie (3) | ± 5 % |
Pic de courant de sortie max. (non récurrent) | ≤ courant de sortie + 35 % |
Courant de sortie à ondulation résiduelle NF (< 120 Hz) | ± 5 % |
Sortie P_ST_LM (à pleine charge) | ≤ 1 |
Sortie SVM (à pleine charge) | ≤ 0,4 |
Tension de sortie max. (U-OUT) | 60 V |
Supporte la tension d'impulsions (entre L et N) | 1 kV |
Supporte la tension d'impulsions (entre L/N et PE) | 2 kV |
Pics de tension côté sortie contre PE | < 500 V |
Degré de protection | IP20 |
Durée de vie | jusqu'à 100.000 h |
Guarantee (conditions at www.tridonic.com) | 5 Année(s) |
Dimensions L x l x H | 235 x 100 x 31 mm |
Caractéristiques techniques spécifiques | |||||||||
---|---|---|---|---|---|---|---|---|---|
Type | Courant de sortie (1) (2) | Tension de sortie min. | Tension de sortie max. | Puissance de sortie max. | Puissance absorbée typique (à 230 V, 50 Hz, pleine charge) | Consommation typique (à 230 V, 50 Hz, pleine charge) | Point tc max. | Température ambiante ta | Valeur de la résistance I-SELECT 2 (3) |
LC 100W 1100-2100mA flexC SR EXC | 1.100 mA | 20 V | 54,0 V | 59,4 W | 65,1 W | 297 mA | 80 °C | -25 ... +50 °C | – |
LC 100W 1100-2100mA flexC SR EXC | 1.150 mA | 20 V | 54,0 V | 62,4 W | 68,1 W | 309 mA | 80 °C | -25 ... +50 °C | 4,35 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 1.200 mA | 20 V | 54,0 V | 64,8 W | 71,4 W | 323 mA | 80 °C | -25 ... +50 °C | 4,17 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 1.250 mA | 20 V | 54,0 V | 68,0 W | 74,0 W | 334 mA | 80 °C | -25 ... +50 °C | 4,00 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 1.300 mA | 20 V | 54,0 V | 70,2 W | 77,0 W | 347 mA | 80 °C | -25 ... +50 °C | 3,85 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 1.350 mA | 20 V | 54,0 V | 73,3 W | 79,7 W | 358 mA | 80 °C | -25 ... +50 °C | 3,70 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 1.400 mA | 20 V | 54,0 V | 75,6 W | 82,1 W | 369 mA | 80 °C | -25 ... +50 °C | 3,57 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 1.450 mA | 20 V | 54,0 V | 78,2 W | 84,8 W | 380 mA | 80 °C | -25 ... +50 °C | 3,45 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 1.500 mA | 20 V | 54,0 V | 81,0 W | 88,1 W | 394 mA | 80 °C | -25 ... +50 °C | 3,33 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 1.550 mA | 20 V | 54,0 V | 83,5 W | 90,5 W | 404 mA | 80 °C | -25 ... +50 °C | 3,23 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 1.600 mA | 20 V | 54,0 V | 86,4 W | 94,1 W | 420 mA | 80 °C | -25 ... +50 °C | 3,13 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 1.650 mA | 20 V | 54,0 V | 89,1 W | 96,5 W | 430 mA | 80 °C | -25 ... +50 °C | 3,03 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 1.700 mA | 20 V | 54,0 V | 91,8 W | 99,3 W | 442 mA | 80 °C | -25 ... +50 °C | 2,94 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 1.750 mA | 20 V | 54,0 V | 93,7 W | 101,6 W | 451 mA | 80 °C | -25 ... +50 °C | 2,86 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 1.800 mA | 20 V | 54,0 V | 97,2 W | 105,7 W | 469 mA | 80 °C | -25 ... +50 °C | 2,78 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 1.850 mA | 20 V | 54,0 V | 99,8 W | 107,9 W | 479 mA | 80 °C | -25 ... +50 °C | 2,70 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 1.900 mA | 20 V | 52,6 V | 99,9 W | 107,8 W | 478 mA | 80 °C | -25 ... +50 °C | 2,63 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 1.950 mA | 20 V | 51,3 V | 99,8 W | 108,0 W | 479 mA | 80 °C | -25 ... +50 °C | 2,56 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 2.000 mA | 20 V | 50,0 V | 100,0 W | 108,1 W | 480 mA | 80 °C | -25 ... +50 °C | 2,50 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 2.050 mA | 20 V | 48,8 V | 100,0 W | 108,4 W | 481 mA | 80 °C | -25 ... +50 °C | 2,44 kΩ |
LC 100W 1100-2100mA flexC SR EXC | 2.100 mA | 20 V | 47,6 V | 100,0 W | 108,5 W | 482 mA | 80 °C | -25 ... +50 °C | 0,00 kΩ |
- (1) Le tableau contient une sélection de points de fonctionnement mais ne couvre cependant pas tous les points. Le courant de sortie peut être réglé dans la plage de courant par pas de 1 mA.
- (2) Le courant de sortie est une valeur médiane.
- (3) Pas compatible avec I-SELECT (génération 1). Valeur de résistance calculée.
Informations complémentaires
- ready2mains™ (http://www.tridonic.fr/fr/products/luxcontrol-ready2mains.asp)
- FAQ – Systèmes LED (http://www.tridonic.fr/fr/faq-led.asp)
- Projets de référence (http://www.tridonic.fr/fr/projets-de-reference.asp)
- Déclarations écologiques (http://www.tridonic.fr/fr/declarations-ecologiques.asp)
- Texte d’adjudication (http://www.tridonic.fr/fr/texte-d-adjudication.asp)
Certificats / Déclarations de conformité | ||
Type | Référence | Certificats |
---|---|---|
Certificats () |
I-SELECT 2 PLUG PRE / EXC Accessoires
Description du produit
- Résistance pré-établie pour le réglage du courant
- Compatible avec les driver LED dotées de l'interface I-select 2 ; pas compatible avec I-SELECT (génération 1)
- La résistance a une isolation de base
- Puissance de la résistance de 0,25 W
- Tolérance électrique de ± 2 % complémentaire pour le courant nominal
- Compatible avec les driver LED des séries PRE et EXC
Exemple de calcul
- R [kΩ] = 5 V / I_out [mA] x 1000
- Utilisation de résistances E96
- Tolérance de la résistance de 1 % ; puissance 0,1 W ; isolation de base requise
- Si une valeur de résistance hors de la plage spécifique est utilisée, le courant minimal (valeur de résistance trop grande) ou maximal (valeur de résistance trop faible) est réglé automatiquement.
Données de commande | |||||||
---|---|---|---|---|---|---|---|
Type | Référence | Couleur | Caractéristique | Courant | Valeur de la résistance | Emballage sac | Poids par pièce |
I-SELECT 2 PLUG 1100MA BL | 28001126 | Bleu | 1100 mA | 1 100 mA | 4,53 kΩ | 10 pièce/pièces | 0,001 kg |
I-SELECT 2 PLUG 1150MA BL | 28001127 | Bleu | 1150 mA | 1 150 mA | 4,32 kΩ | 10 pièce/pièces | 0,001 kg |
I-SELECT 2 PLUG 1200MA BL | 28001128 | Bleu | 1200 mA | 1 200 mA | 4,12 kΩ | 10 pièce/pièces | 0,001 kg |
I-SELECT 2 PLUG 1250MA BL | 28001129 | Bleu | 1250 mA | 1 250 mA | 4,02 kΩ | 10 pièce/pièces | 0,001 kg |
I-SELECT 2 PLUG 1300MA BL | 28001130 | Bleu | 1300 mA | 1 300 mA | 3,83 kΩ | 10 pièce/pièces | 0,001 kg |
I-SELECT 2 PLUG 1350MA BL | 28001131 | Bleu | 1350 mA | 1 350 mA | 3,74 kΩ | 10 pièce/pièces | 0,001 kg |
I-SELECT 2 PLUG 1400MA BL | 28001132 | Bleu | 1400 mA | 1 400 mA | 3,57 kΩ | 10 pièce/pièces | 0,001 kg |
I-SELECT 2 PLUG 1500MA BL | 28001133 | Bleu | 1500 mA | 1 500 mA | 3,32 kΩ | 10 pièce/pièces | 0,001 kg |
I-SELECT 2 PLUG 1600MA BL | 28001134 | Bleu | 1600 mA | 1 600 mA | 3,16 kΩ | 10 pièce/pièces | 0,001 kg |
I-SELECT 2 PLUG 1700MA BL | 28001135 | Bleu | 1700 mA | 1 700 mA | 2,94 kΩ | 10 pièce/pièces | 0,001 kg |
I-SELECT 2 PLUG 1800MA BL | 28001136 | Bleu | 1800 mA | 1800 mA | 2,80 kΩ | 10 pièce/pièces | 0,001 kg |
I-SELECT 2 PLUG 1900MA BL | 28001137 | Bleu | 1900 mA | 1900 mA | 2,61 kΩ | 10 pièce/pièces | 0,001 kg |
I-SELECT 2 PLUG 2000MA BL | 28001138 | Bleu | 2000 mA | 2000 mA | 2,49 kΩ | 10 pièce/pièces | 0,001 kg |
I-SELECT 2 PLUG 2100MA BL | 28001139 | Bleu | 2100 mA | 2 100 mA | 2,37 kΩ | 10 pièce/pièces | 0,001 kg |
I-SELECT 2 PLUG MAX BL | 28001099 | Bleu | MAX | MAX | 0,00 kΩ | 10 pièce/pièces | 0,001 kg |
CAD / RAY | ||
---|---|---|
Type | Référence | Documents CAD |
I-SELECT 2 PLUG 1100MA BL | 28001126 | CAD (712,6 Ko) |
I-SELECT 2 PLUG 1150MA BL | 28001127 | CAD (712,6 Ko) |
I-SELECT 2 PLUG 1200MA BL | 28001128 | CAD (712,6 Ko) |
I-SELECT 2 PLUG 1250MA BL | 28001129 | CAD (712,6 Ko) |
I-SELECT 2 PLUG 1300MA BL | 28001130 | CAD (712,6 Ko) |
I-SELECT 2 PLUG 1350MA BL | 28001131 | CAD (712,6 Ko) |
I-SELECT 2 PLUG 1400MA BL | 28001132 | CAD (712,6 Ko) |
I-SELECT 2 PLUG 1500MA BL | 28001133 | CAD (712,6 Ko) |
I-SELECT 2 PLUG 1600MA BL | 28001134 | CAD (712,6 Ko) |
I-SELECT 2 PLUG 1700MA BL | 28001135 | CAD (712,6 Ko) |
I-SELECT 2 PLUG 1800MA BL | 28001136 | CAD (712,6 Ko) |
I-SELECT 2 PLUG 1900MA BL | 28001137 | CAD (712,6 Ko) |
I-SELECT 2 PLUG 2000MA BL | 28001138 | CAD (712,6 Ko) |
I-SELECT 2 PLUG 2100MA BL | 28001139 | CAD (712,6 Ko) |
I-SELECT 2 PLUG MAX BL | 28001099 | CAD (712,6 Ko) |
CAD / RAY | ||
---|---|---|
Type | Référence | Documents CAD |
LC 100W 1100-2100mA flexC SR EXC | 28001573 | CAD (1,2 Mo) |
EPD | ||
---|---|---|
Type | Référence | Déclaration environnementale (EPD) |
LC 100W 1100-2100mA flexC SR EXC | 28001573 | EPD |